Compact laser gas leak detector
Applications:
SF6 leak detector "KARAT" is designed for high sensitivity leak testing of SF6, freons and other gases from the vessels under overpressure. Due to using of the compact pulse - periodic laser and special photo-acoustical detector (PAD) the sensitivity of SF6 detecting at a level 1x10-9 cc/sec or 0.2 mg/year is reached. This is much higher in a comparison with electro discharge, halogen and helium leak detectors in sniffing mode.
- SF6 leak detector “KARAT” allows to detect SF6 leakage at a level 1x10-9 cc3/sec or 0,2 mg/year.
- Monitoring of SF6 leakage on power stations, in chemical, aerospace, communication and other productions.
- All areas of a science and engineering connected to use of tight gas systems and volumes, gas pipelines, vacuum systems and so on.
Laser Gas Leak Detector KARAT
Key features:
- The detector has the air pump for delivery of air sample to PAD.
- Detector contain the control panel is equipped with a telescopic sample intake and a light volume indicator.
- The detector is activated and deactivated with help of the hand-held control panel, which indicates the current concentration of the gas under study and laser output power.
- The indications of the light volume indicator are duplicated by beep.
- Micro processor in the control circuit of the detector allows to set an optimum mode of power consumption for switching on and under measurements, to connect if necessary detector to computer USB port for testing.
- SF6 leak detector operates in real time mode. The actual speed (< 1 sec) is determined by time of delivery of gas sample to PAD.
Benefits:
- Ultra high sensitivity for operation in real time mode;
- No need calibration;
- No radioactive detector;
- No argon or other gas required;
- No training required, switch on and go;
- No high voltage;
- Both 12 VDC (battery) or 90~264 VAC, 120~370 VDC power supply;
- Large leaks present no contamination problem;
- Small sizes and weight;
- Low cost.
Technical parameters:
Operation mode sniffing
Gas marker SF6
Sensitivity to SF6 leaks ~1x10-9 cc/sec (~0.2 mg/year)
Gas marker concentration in gas carrier, no more than 0.01-0.1 % (100-1000 ppm)
Type of detector PAD
Radiation source / wavelength / average power CO2-laser / 10.6 mkm / ~1 W
Start-up time, no more than 0.5 min
Cooling air cooled
Air sample flow rate, no more than 0.5 l/min
Computer connect USB port
Voltage supply / power consumption 12 VDC (battery) or 90~264 VAC, 120~370 VDC / 45 VA
Time of continuous operation at one battery charging (12 V, 12 Ah), no less than 2.5 h
Size, no more than:
- leak detector
- control panel
- length of telescopic intake

465x192x112 mm
240x53x25 mm
147 – 900 mm
Weight, no more than:
- leak detector
- control panel

5.4 kg
0.15 kg
Contact us for more information.
For sales in South Korea you should contact Mr. Chang-Myung Lee, SCIEN Co., Ltd., 306 H0 Hanla Bld. Ok-Dong, Nam-Gu, Ulsan, Republic of Korea 680-845 sales@lc-solutions.com