Special technologies, Ltd.
Russian version

Direct shortcuts to our products

CO2-lasers and systems:

- leak detector SF6 LaserGasTest
- medical gas-analyzer
- special gas-analyzers
- compact CO2-lasers
- tunable CO2-lasers
- RF generators
- nonlinear crystals

Contact information:


Russian Federation
Special technologies, Ltd.
Head Office:
Zeljonaja gorka str. 1/3,
630060, Novosibirsk,
Russian Federation
Phone/Fax: +7 (383) 334 80 81

e-mail: sales@lc-solutions.com
Authorized Distributor in Russia
for SF6 LaserGasTest system:
NTC-EDS, Ltd.
Krasnokazarmennaja str. 17,
111250, Moscow,
Russian Federation
Phone/Fax: +7 (495) 918 05 11

e-mail: info@ntc-eds.ru
Japan South Korea
Authorized Exclusive Distributor for Japan and South Korea
for SF6 LaserGasTest system:
Aims Corporation
2-23-11, Narusegaoka
Machida, Tokyo 194-0011
Japan
Phone: +81-42-799-0606
Fax: +81-42-799-0604

e-mail: info@aimscorp.jp
back to Home page

Medical photo-acoustic gas analyzer LGA-2
system for analysis of expired air

Description:
Laser Photo-Acoustic Gas Analyzer LGA-2 is based on tunable waveguide RF excited CO2 laser and resonant photo-acoustic detector. The system is applied for:
- Absorption spectral analysis of expired air and detection of gas markers of various human diseases,
- Local gas analysis of the air in 9…11 mkm spectral range,
- Search and measurement of low concentration of gas impurities in the atmosphere.
Medical photo-acoustic gas analyzer
Application sample:
This system is used in Siberian State Medical University for researches on detection of gas markers of different human deseases in the expired air.
There is several times less oxygen in the expired air than in the atmosphere. Much more carbon dioxide. And about 100% relative humidity. And more than 400 different gas compounds, a lot of which are endogenous.
Together with the main atmospheric gases there could be gas-bio-markers of different deseases like CO, NO, CH4, NH3, C2H4, H2O2, CH3COCH2, etc. in the expired air.
Use of CO2-laser source for analysis allows to produce up to 100 lines of generation in spectral range 910-980 and 1040-1090 cm-2. Thereby, in one measurement run it is possible to get absorption coefficient scan of the analyzed air in spectral range from 9 to 11 mkm.
Technical Specifications:
Gases under control O3, CH4, NH3, C2H4, C6H6, H2O, CH3OH, C2H5OH, CO2, SF6, Freons, etc.
Detection mode Expired air sampling
System control PC
PC interface USB
Result Displaying Mode graphic
Detector Type photo-acoustic
Internal detector volume 15 cm3
Sensitivity to SF6 1 ppb
Dinamic range in terms of SF6 1 ppb to 10 ppm
Accuracy 10%
Intake air flow 0.6 l/min
Air intake time 2 sec
Laser source
spectral tuning range
generation lines number
average power
CO2-laser
9.2 - 10.8 mkm
>40
1 W
Spectrum analysis time 5 min
Start-up time 1 min
Cooling air
Continious operation time no limit
Power supply 220 V/50(60) Hz
Power consumption 150 VA
Dimensions 750x310x130 mm
Weight 14 kg
Powered by: Special technologies, Ltd. © 2010